UPTIMEDC PLATFORM

UptimeDC capabilities

UptimeDC is a DCIM platform for building a current, shared model of Data Center infrastructure. It connects device and rack inventory, 2D/3D views, power and network connections, operational data, capacity planning and change processes.

It does not force the replacement of every tool already used by the organisation. It organises data about physical infrastructure and its dependencies, then can enrich it with SNMP, BMS, CMDB, Service Desk and other-system data. IT, Facilities and Data Center Operations can therefore work from the same context - from a single port, through a rack, to multiple locations.

From room plan to device data

UptimeDC supports management of multiple data centers and locations. The model can be extended with custom object types, while asset information can be imported or exported, including CSV and XML formats.

The same infrastructure model supports further areas of work.

Asset & inventory

Inventory with operational context

One model can describe devices, racks, locations and their attributes. Reports help find assets by parameters, while identification, service and technical data stays with the relevant object.

Which information is included?

  • Name, manufacturer, model, serial number and identifiers
  • Location, administrator, warranty and service information
  • Free space plus rack and floor load
  • Technical parameters such as CPU, RAM, operating system and firmware

What does it support?

  • Find a device or rack faster using multiple criteria
  • Keep technical and operational documentation together
  • Report expiring warranties and maintenance
  • Reduce manual inventory work during an audit or change

2D / 3D

Visualisation from data center to device

2D and 3D views turn the data model into a readable view of a room, rack and device. They enable navigation from the top-level plan to asset detail without switching between separate diagrams.

What can be shown?

  • Room plan: walls, doors, aisles and cable channels
  • Views and technical layers, such as raised floor or suspended ceiling
  • Rack mount and device views: front and back
  • Space, power, weight, heat and port utilisation scales

What does it support?

  • Faster understanding of physical context
  • Drill down from location to a specific device
  • Visual indication of constraints and availability
  • Clearer conversation across IT, Facilities and Operations

Capacity & planning

Capacity as a set of constraints

Capacity planning in UptimeDC is not only a count of free U. The model can cover front and rear rack space, contiguous free space, weight, floor load, power, heat and available network ports.

What is measured?

  • Front and rear free space plus the largest contiguous free area
  • Total and remaining rack load capacity
  • Floor-load usage and remaining capacity
  • Power utilisation, generated heat and available ports

What does it support?

  • Assess where the next device can be safely installed
  • Plan growth without relying on outdated documentation
  • Find constraints before they become execution issues
  • Prepare migrations and rack-layout changes better

Logical relations

Dependencies invisible on the floor plan

Logical relations complement cabling and power with parent and child dependencies between physical and logical components. The model can also represent service and application structure.

What can be linked?

  • A device with parent and child components
  • A physical component with a logical component
  • Multiple relationships in a parent / child structure
  • A relationship view after the model is saved

What does it support?

  • Better understanding of the effect of technical changes
  • Navigation from a device to its logical dependencies
  • More consistent infrastructure and service documentation
  • Controlled addition and removal of relationships

Monitoring & SNMP

Live data in the infrastructure model

SNMP configuration enables selected device attributes to be read in real time. Instead of a separate list of readings, values can be assigned to the asset they actually relate to.

How does it work?

  • Assign OIDs to predefined real-time attributes
  • SNMP v1, v2c and v3 support
  • Refresh, timeout, retry and unit multiplier settings
  • A real-time data source assigned to the relevant object

What does it support?

  • Live data at device, PDU or rack level
  • Reports on power, current, voltage, temperature and humidity
  • Context for capacity decisions and diagnostics
  • An infrastructure model enriched with BMS data through a dedicated connector

Automation, tasks & dashboards

Repeatable work as a controlled process

The system enables procedures, tasks and automation policies. Data changes are recorded, while users can use dashboards and workspaces aligned to their permissions.

What does it organise?

  • Standalone tasks or external workflow integration
  • Automatic task generation and configurable policies
  • Logical and technical validation of operations
  • History of asset-data modifications

What does it support?

  • Fewer steps performed only from memory
  • Easier change-status control
  • Repeatable procedures for the appropriate roles
  • Dashboards with capacity, power, network and report data

Integrations & trackers

DCIM as part of the existing ecosystem

Trackers synchronise with external systems. They can report differences or update data, cover individual devices or whole locations, and produce a report for every synchronisation.

What can it work with?

  • CMDB, VMware, Microsoft Hyper-V, Zabbix, Jira Insight, Ralph and ITAM
  • BMS Generic Connector for sensor states, readings and alarm conditions
  • CSV files over FTP or SFTP for BMS Generic Connector
  • API and tailored integrations depending on scope

What does it support?

  • Less manual data re-entry between tools
  • Difference reporting before updates or controlled synchronisation
  • Scheduled or forced refreshes and email reports
  • Extension of the model without replacing the full tool landscape

Power and Networking: a dependency model, not just an asset list.

Power management

Power from a device to its path

UptimeDC can connect device power ports and document their relationships in a diagram. Information about servers, PDUs, racks and power draw no longer has to remain in separate sheets or in team knowledge.

Which data can be modelled?

  • Incoming and outgoing power ports
  • Port-to-port connections in Power Diagram Editor
  • Rated power, a user-defined value or a live SNMP value
  • Rack power usage calculated for devices mounted in the rack

What does it support?

  • Power Connections report to organise power relationships by device
  • Power Params report: used and free ports plus power values
  • Power Charts for current draw and heat
  • Failure Simulations Diagram to analyse failure scenarios using modelled connections

Network & cabling

Network and cabling from port to port

Network Table Editor is a specialised tool for building and documenting physical network connections. Operators work with devices, their ports and cable models, while the system shows the path of a created connection.

What does it cover?

  • UTP, FO, MTP, QSFP and SFP cables
  • 1:1 and 1:many connections, such as MTP-4x LC or QSFP-4x SFP
  • Devices from other locations added to the connection list
  • Automatic cable naming using a defined format

What does it control?

  • Port and slot type validation before a connection is created
  • Cable usage state: free, connected at one end or at both ends
  • Connection path displayed after selecting a cable or port
  • Disconnecting and updating documentation with a physical change

Choose scope around a real problem

An implementation can begin with a reliable inventory, room model and power or network relationships, then expand with monitoring, integrations and automation. The scope should reflect available data, team processes and the business goal.